Fluke PS410 Patient Simulator
Reliable Patient Simulation for Accurate Clinical Testing
Product Overview
Fluke PS410 Patient Simulator Price in Bangladesh
Fluke PS410 Patient Simulator is a compact and reliable biomedical testing device designed for accurate simulation of patient vital signs, and professionals searching for Fluke PS410 Patient Simulator Price in Bangladesh often choose this model for its simplicity, portability, and dependable performance in clinical environments. It is widely used in hospitals, biomedical engineering departments, and medical training facilities for efficient patient monitor testing and validation.
Built for ease of use, the Fluke PS410 provides a straightforward interface that allows technicians to perform essential patient monitoring tests quickly and accurately. Its compact design ensures excellent portability, making it easy to carry between departments or use in field service environments. This helps improve workflow efficiency while maintaining consistent and reliable testing performance.
The simulator delivers accurate and repeatable physiological signals, supporting preventive maintenance and quality assurance programs in healthcare settings. By simulating key patient parameters, it ensures that monitoring systems function correctly under real clinical conditions. This contributes to improved equipment reliability and enhanced patient safety in medical environments.
Designed with durability in mind, the Fluke PS410 is built to withstand regular use in demanding healthcare and training environments. Its robust construction ensures long term operational stability, while its lightweight design offers convenience for biomedical professionals who require flexible testing solutions.
In addition to its simulation accuracy, the Fluke PS410 supports compliance with healthcare standards by enabling efficient verification of patient monitoring equipment. Its combination of accuracy, durability, portability, and ease of use makes it a trusted choice for professionals who require dependable biomedical testing and patient simulation solutions.
Specifications
Specifications: Fluke PS410 Patient Simulator
ECG Simulation
-
Normal Sinus Rhythm: 12-lead with independent outputs referenced to RL.
-
Selectable Rates: 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, and 300 BPM.
-
Accuracy: ±1%.
-
Output Impedance: 940 Ω between leads.
-
ECG Amplitudes: 0.5, 1, and 2 mV.
-
Amplitude Accuracy: ±2% (Lead II).
-
High-Level Output: 1000x Lead II.
-
Waveforms: Square wave (2 Hz, 0.125 Hz), Pulse (30, 60, 120 BPM; 60 ms pulse width), Sine waves (0.5, 5, 10, 40, 50, 60 Hz at 1 mV amplitude), Triangle wave (2 Hz).
-
ST Segment Analysis: Elevated or depressed from -0.6 mV to 6 mV in 0.2 mV steps.
Arrhythmia Selections
-
Pacemaker Rhythms: Pacer non-capture, Pacer non-function, Demand pacer with occasional or frequent sinus, A-V sequential.
-
Artifacts: 50 Hz, 60 Hz, Muscle, Baseline, Respiration.
-
PVCs: Left and right ventricular focus, early, R on T, bigeminy, trigeminy, multi-focal, frequent multi-focal.
-
Ventricular Rhythms: PVCs at various rates, Ventricular tachycardia, Ventricular fibrillation (full and 1/2 size).
-
Supraventricular Rhythms: Supraventricular tachycardia, Premature atrial/nodal contraction, Asystole, Missed beat, Nodal rhythm, Irregular rhythm.
-
Atrial Rhythms: Atrial flutter, Atrial fibrillation (full and 1/2 size), Atrial tachycardia.
-
Heart Blocks: First-degree, Second-degree, Third-degree.
-
Bundle Branch Blocks: Right and Left bundle-branch block.
Pacemaker Simulation
-
Modes: Demand pacer with occasional or frequent sinus, A-V sequential.
-
Artifacts: 50 Hz, 60 Hz, Muscle, Baseline, Respiration.
General Specifications
-
Display: 2-line LCD.
-
Controls: 6 control keys; ON/OFF power switch.
-
Power: 9V battery or battery eliminator.
-
Housing: ABS plastic case.
-
Dimensions: 11.3 cm L x 7 cm W x 3.4 cm H (6.1 in L x 3.7 in W x 1.3 in H).
-
Weight: 0.4 kg (0.9 lb).
-
Operating Temperature: 15 °C to 35 °C (59 °F to 95 °F).
-
Storage Temperature: 0 °C to 50 °C (32 °F to 122 °F).
Features
Key Features: Fluke PS410 Patient Simulator
• Handheld
• 12-lead ECG simulation
• 12 arrhythmia selections
• Universal ECG jacks
• Auto sequencing of performance waveforms
• Battery operated
• PS410/DPM1B Bundle kit with custom carrying case for quick ECG/NIBP patient monitor testing