Hioki LR8102 Modular Data Logger
Advanced Modular Data Logging for High Precision Industrial Analysis
Product Overview
Hioki LR8102 Modular Data Logger Price in Bangladesh
Hioki LR8102 is designed for advanced industrial measurement and high speed data acquisition, making Hioki LR8102 Modular Data Logger Price in Bangladesh a powerful solution for battery testing, power analysis, and complex system monitoring applications. Built for professional engineers and research environments, this modular data logger delivers accurate synchronized measurement performance for demanding industrial operations.
The LR8102 supports flexible modular expansion, allowing users to configure voltage, temperature, and power measurement channels according to specific testing requirements. It can synchronize multiple loggers for large scale measurement systems, making it suitable for high channel count applications in electric vehicle battery testing, renewable energy systems, and industrial automation. Its advanced real time data transfer capability and fast update interval help users capture highly detailed measurement data with excellent reliability.
Designed for embedded and rack mount integration, the Hioki LR8102 provides stable long term monitoring with advanced connectivity features including LAN, CAN, and optical synchronization support. The logger is compatible with Hioki voltage temperature modules and power measurement modules, enabling precise high voltage and high current analysis in research laboratories and production facilities. Its enhanced noise resistance and scalable architecture make it ideal for complex testing environments requiring dependable and accurate measurement performance.
Hioki LR8102 is widely used in battery development, inverter testing, energy storage research, and industrial system diagnostics. Professionals value its modular flexibility, high precision performance, and ability to handle large scale synchronized measurements efficiently. Industry discussions also highlight Hioki products for their reliability and dependable long term data logging capability in professional engineering applications.
Key Features: Hioki LR8102 Modular Data Logger
- Add measurement modules as needed to create the measurement system you need
- [LR8102] Add channels by synchronizing sampling across multiple loggers
- [LR8102] Transfer high-speed data in real time
Specifications
General specifications: Hioki LR8102 Modular Data Logger
| Product model | Data Logger LR8102 | Data Logger LR8101 |
|---|---|---|
| Modules that can be connected | See [Options] > [Connectable measurement modules] | |
| Maximum number of module connections | 10 | |
| Maximum number of synchronizable loggers | 10 (Requires optical connection cables) |
N/A |
| Power supply | AC adapter: AC Adapter Z1016 (operates on 12 V DC ±10%) External power supply: 10 V DC to 30 V DC AC Power Module M1100: Always required when using the Power Measurement Module M7103. |
|
| Operating temperature and humidity range | −10°C to 50°C (14°F to 122°F), 80% RH or less (non-condensing) | |
| Number of LAN ports | 2 | 1 |
| Communication interface | [LAN1 functionality] Collecting data and setting recording conditions using Logger Utility Setting the initial IP address using Logger Utility Setting and controlling recording using communication commands Manually acquiring data using an FTP Server Automatically sending data via FTP (FTP client) HTTP server function XCP on Ethernet (TCP) NTP client function [LAN2 functionality] XCP on Ethernet (UDP) Measurement data can be output by UDP |
[LAN1 functionality] Collecting data and setting recording conditions using Logger Utility Setting the initial IP address using Logger Utility Setting and controlling recording using communication commands Manually acquiring data using an FTP Server Automatically sending data via FTP (FTP client) HTTP server function XCP on Ethernet (TCP) NTP client function |
| External media | USB Drive, Operation guaranteed: Z4006 (16 GB) SD memory card/SDHC memory card supported, Operation guaranteed: Z4001 (2 GB), Z4003 (8 GB) |
|
| External control terminal | Pulse/logic input (1), External sampling input (1), External input and output (4), Alarm output (4), GND terminal (5), CAN interface (1) | Pulse/logic input (1), External sampling input (1), External input and output (4), Alarm output (4), GND terminal (5) |
| Dimensions and weight | - No module: Approx. 80W × 166H × 238D mm (3.1W × 6.5H × 9.4D in.) (excluding protruding parts), Approx. 1.5 kg (3.3 lbs) - With one M7100 installed: Approx. 134W × 166H × 263D mm (5.3W × 6.5H × 10.4D in.) (excluding protruding parts) - With ten M7100 installed: Approx. 620W × 166H × 263D mm (24.4W × 6.5H × 10.4D in.) (excluding protruding parts) |
|
| Included accessories | Operating Precautions ×1, Startup Guide ×1, DVD ×1 (Startup Guide, Instruction Manual, Logger Utility, Logger Utility Instruction Manual, CAN Editor, CAN Editor Instruction Manual, Communication Command Instruction Manual) | |