Kyoritsu KEW 6016 Multi Function Tester
All in one advanced electrical installation testing solution
Product Overview
Kyoritsu KEW 6016 Multi Function Tester Price in Bangladesh
Kyoritsu KEW 6016 Multi Function Tester Price in Bangladesh is widely searched by electrical engineers and industrial technicians who need a reliable and advanced solution for comprehensive electrical installation testing. Kyoritsu KEW 6016 Multi Function Tester Price in Bangladesh reflects the demand for a high performance instrument designed for insulation, loop impedance, RCD, PSC, PFC, and earth testing in professional electrical environments.
The Kyoritsu KEW 6016 is a multifunction electrical tester that combines several critical testing functions into one device, making it highly efficient for field engineers and maintenance professionals. It is used to verify electrical safety, test insulation resistance, measure loop impedance, evaluate RCD performance, and calculate prospective fault conditions, ensuring complete analysis of electrical systems.
This advanced tester is designed with high accuracy and stability, making it suitable for industrial plants, construction sites, commercial buildings, and power distribution systems. It provides consistent measurement results even in demanding environments, helping professionals detect faults, verify system integrity, and ensure compliance with electrical safety standards.
The device features user friendly operation with a clear display and intuitive controls, allowing technicians to perform complex tests efficiently. It supports multiple measurement modes, enabling comprehensive evaluation of electrical installations without the need for multiple separate instruments. Its portable and rugged design ensures durability and long term reliability in field conditions.
Overall, the Kyoritsu KEW 6016 Multi Function Tester is a trusted solution for professional electrical testing applications. It combines precision, multifunction capability, and durability, making it an essential tool for engineers and technicians involved in electrical installation testing and maintenance work.
Key Features: Kyoritsu KEW 6016 Multi Function Testers
- Continuity measurements up to 2000Ω
- Three phase rotation testing
- RCD testing with ramp and autotest functions
- Lockdown test button for "hands-free testing"
- Calculation of Prospective Short Current (PSC) and Prospective Fault Current (PFC).
- Loop impedance testing including phase to phase loops.
- Measures AC voltages up to 500V (includes frequency of voltage).
- Earth resistance measurements up to 2000Ω
-
Supplied with carry case, test leads, auxiliary spikes and software.
Specifications
Specifications: Kyoritsu KEW 6016 Multi Function Testers
| Continuity | ||||||||
|---|---|---|---|---|---|---|---|---|
| Range | 20/200/2000Ω (Auto-ranging) | |||||||
| Open circuit voltage (DC) |
5V±20% (*1) | |||||||
| Short circuit current |
Greater than 200mA | |||||||
| Accuracy | ±0.1Ω (0 - 0.19Ω) ±2%rdg+8dgt (0.2 - 2000Ω) |
|||||||
| Insulation Resistance | ||||||||
| Range | 20/200MΩ (Auto-ranging) |
20/200/2000MΩ (Auto-ranging) | ||||||
| Open circuit voltage (DC) |
250V+25% -0% | 500V+25% -0% | 1000V+20% -0% | |||||
| Rated current | 1mA or greater @ 250kΩ |
1mA or greater @ 500kΩ |
1mA or greater @ 1MΩ |
|||||
| Accuracy | ±2%rdg+6dgt (0 - 19.99MΩ) ±5%rdg+6dgt (20 - 200MΩ) |
±2%rdg+6dgt (0 - 199.9MΩ) ±5%rdg+6dgt (200 - 2000MΩ) |
||||||
| Loop Impedance | ||||||||
| Function | L-PE | L-PE (ATT) | L-N / L-L | |||||
| Rated Voltage | 100 - 260V 50/60Hz | L-N: 100 - 300V L-L: 300 - 500V 50/60Hz |
||||||
| Nominal Test Current at 0Ω External Loop: Magnitude/ Duration (*2) |
20Ω: 6A/20ms 200Ω: 2A/20ms 2000Ω: 15mA/500ms |
L-N: 6A/60ms N-PE: 10mA/approx. 5s |
20Ω: 6A/20ms | |||||
| Range | 20/200/2000Ω (Auto-ranging) |
20/200/2000Ω (Auto-ranging) (L-N < 20Ω) |
20Ω | |||||
| Accuracy | ±3%rdg+4dgt(*3) ±3%rdg+8dgt(*4) |
±3%rdg+6dgt (*3) ±3%rdg+8dgt(*4) |
±3%rdg+4dgt (*3) ±3%rdg+8dgt(*4) |
|||||
| PSC (L-N / L-L) / PFC (L-PE) | ||||||||
| Function | PSC | PFC | PFC (ATT) | |||||
| Rated Voltage | 100 - 500V 50/60Hz | 100 - 260V 50/60Hz | ||||||
| Nominal Test Current at 0Ω External Loop: Magnitude/ Duration (*5) |
6A/20ms | 6A/20ms 2A/20ms 15mA/500ms |
L-N: 6A/60ms N-PE: 10mA/approx. 5s |
|||||
| Range | 2000A/20kA Auto-Ranging | |||||||
| Accuracy | PSC / PFC accuracy is derived from measured loop impedance specification and measured voltage specification |
|||||||
| RCD | ||||||||
| Function | X1/2 | X1 | X5 | Ramp | Auto | |||
| Trip current setting |
10/30/100/300/ 500/1000mA |
10/30/ 100mA |
10/30/ 100/300/ 500mA |
Depending on the accuracy at each function. Measurement sequence: X1/2 0°→X1/2 180° →X1 0°→X1 180° →X5 0°→X5 180° Measurements with x5 are not carried out for RCDs with nominal current of 100mA or more. |
||||
| Trip current Duration |
2000ms | G: 550ms S: 1000ms |
410ms | Goes up by 10% from 20% to 110% G:300ms/ S:500ms X10 times |
||||
| Rated Voltage | 230V+10%-15% 50/60Hz | |||||||
| Accuracy | AC Type: -8% - -2% A Type: -10% - 0% |
AC Type: +2% - +8% A Type: 0% - +10% |
AC Type: ±4% A Type: ±10% |
|||||
| Trip time: ±1%rdg+3dgt | ||||||||
| RCD (Uc) | ||||||||
| Function | UC | |||||||
| Rated Voltage | 230V+10% - 15% 50/60Hz | |||||||
| Range | 100.0V | |||||||
| Test current | ≤ 1/2IΔn (max150mA) | |||||||
| Accuracy | +5% - +15%rdg, ±8dgt | |||||||
| Earth | ||||||||
| Range | 20/200/2000Ω Auto-Ranging | |||||||
| Accuracy | 20Ω: ±3%rdg+0.1Ω 200/2000Ω: ±3%rdg+3dgt (Auxiliary earth resistance 100±5%) |
|||||||
| Phase Rotation | ||||||||
| Rated Voltage | 50-500V 50/60Hz | |||||||
| Remarks | Correct phase sequence: are displayed "1.2.3" and cycle markReversed phase sequence: are displayed "3.2.1" and cycle mark |
|||||||
| Volts | ||||||||
| Function | Volts | Frequency | ||||||
| Rated Voltage | 25 - 500V, 45 - 65Hz | |||||||
| Measuring range | 25 - 500V | 45 - 65Hz | ||||||
| Accuracy | ±2%rdg+4dgt | ±0.5%rdg+2dgt | ||||||
| Applicable standards | IEC 61010-1 CAT III 300V (500V L to L) Pollution degree 2, IEC 61010-031, IEC 61557-1, 2, 3, 4, 5, 6, 7, 10, IEC 60529 (IP40), IEC 61326 (EMC) |
|---|---|
| Power source | LR6 X 8 |
| Dimensions | 136(L) X 235(W) X 114(D)mm |
| Weight | 1350g (including batteries.) |
| Included Accessories | 7188A (Distribution board fuse test lead set) 7196A (Test leads with remote control switch) 7218A (Power cord [EU]) (*6) 7228A (Earth resistance test leads) 8032 (Auxiliary earth spikes) 8212-USB (USB adaptor with KEW Report (Software)) 9142 ( Carrying case) 9121 (Shoulder strap) Cord case, Buckle, Battery, Instruction manual |
| Optional Accessories | 8212-RS232C (RS232C adaptor with KEW Report (Software)) |
cycle mark