Fluke 120B Series Industrial ScopeMeter handheld Oscilloscopes
Rugged All-in-One Oscilloscope for Industrial Diagnostics
Product Overview
Fluke 120B Series Industrial ScopeMeter handheld Oscilloscopes Price in Bangladesh
Fluke 120B Series Industrial ScopeMeter is a professional handheld oscilloscope and diagnostic tool, and users searching for Fluke 120B Series Industrial ScopeMeter Price in Bangladesh are typically interested in its industrial-grade performance, portability, and advanced troubleshooting capabilities. This device is widely used by electrical engineers, maintenance technicians, and industrial service professionals for fast and accurate system diagnostics.
The Fluke 120B Series combines three essential tools in one compact unit: an oscilloscope, a digital multimeter, and a high-speed recorder. This integration allows users to measure, analyze, and record electrical signals efficiently without switching between multiple instruments. It is designed for industrial electrical systems, automation equipment, and electro-mechanical troubleshooting tasks.
It offers dual-input measurement capability with oscilloscope bandwidth options up to 20 MHz or 40 MHz depending on the model, making it suitable for a wide range of signal analysis applications. The device also includes intelligent triggering technology such as Connect-and-View™, which automatically stabilizes waveforms for faster diagnostics.
Another key advantage is its built-in recording function, which allows users to capture long-term trends and intermittent faults. This is particularly useful in industrial environments where electrical issues may not appear consistently. The ScopeMeter also supports Fluke Connect® and FlukeView® software for data sharing, analysis, and reporting.
Designed for rugged field use, the Fluke 120B Series features a tough housing that withstands harsh industrial environments. Its portable design makes it ideal for on-site troubleshooting, especially in power systems, manufacturing plants, and maintenance operations where reliability is critical.
The device also integrates advanced measurement features such as automatic scaling, waveform analysis, and multi-function display capabilities, improving workflow efficiency for technicians. Its clear display and intuitive controls make it easier to interpret complex electrical signals in real time.
Overall, the Fluke 120B Series ScopeMeter is a high-performance diagnostic solution for professionals in Bangladesh who need accurate, reliable, and portable test equipment for industrial electrical troubleshooting and maintenance tasks.
Key features: Fluke 120B Series Industrial ScopeMeter handheld Oscilloscopes
- Dual-input digital oscilloscope and multimeter in a ScopeMeter® test tool
- Available with a 40 MHz or 20 MHz oscilloscope bandwidth
- Features Connect-and-View™ trigger simplicity for hands-off operation
- Includes IntellaSet™ technology to automatically and intelligently adjust numerical readout based on measured signal
- Provides a dual-input waveform and meter reading recorder for trending data over extended periods
Specifications
Specifications: Fluke 120B Series Industrial ScopeMeter handheld Oscilloscopes
| Oscilloscope mode | ||
| Vertical | ||
| Frequency response - dc coupled | Without probes and test leads (with BB120) | 123B: dc to 20 MHz (-3 dB) 124B and 125B: dc to 40 MHz (-3 dB) |
| With STL120-IV 1:1 shielded test leads | DC to 12.5 MHz (-3 dB) / dc to 20 MHz (-6 dB) | |
| With VP41 10:1 Probe | 123B: dc to 20MHz (-3 dB) 124B and 125B: dc to 40 MHz (-3 dB) |
|
| Frequency response - ac coupled (lf roll off) | Without probes and test leads | <10 Hz (-3 dB) |
| With STL120-IV 1:1 shielded test leads | <10 Hz (-3 dB) | |
| With VP41 10:1 Probe | <10 Hz (-3 dB) | |
| Rise time, excluding probes, test leads |
123B <17.5 ns 124B and 125B <8.75 ns |
|
| Input impedance | Without probes and test leads | 1 MΩ//20 pF |
| With BB120 | 1 MΩ//24 pF | |
| With STL120-IV 1:1 shielded test leads | 1 MΩ//230 pF | |
| With VP41 10:1 Probe | 5 MΩ//15.5 pF | |
| Sensitivity | 5 mV to 200 V/div | |
| Analog bandwidth limiter | 10 kHz | |
| Display modes | A, -A, B, -B | |
| Max. input voltage A and B | Direct, with test leads, or with VP41 Probe | 600 Vrms Cat IV, 750 Vrms maximum voltage. |
| With BB120 | 600 Vrms | |
| Max. floating voltage, from any terminal to ground | 600 Vrms Cat IV, 750 Vrms up to 400Hz | |
| Horizontal | ||
| Scope modes | Normal, Single, Roll | |
| Ranges (normal) | Equivalent sampling | 123B: 20 ns to 500 ns/div, |
| 124B and 125B: 10 ns to 500 ns/div | ||
| Real time sampling | 1 μs to 5 s/div | |
| Single (real time) | 1 μs to 5 s/div | |
| Roll (real time) | 1s to 60 s/div | |
| Sampling rate (for both channels simultaneously) | Equivalent sampling (repetitive signals) | Up to 4 GS/s |
| Real time sampling 1 μs to 60 s/div | 40 MS/s | |
| Trigger | ||
| Screen update | Free run, on trigger | |
| Source | A, B | |
| Sensitivity A and B | @ DC to 5 MHz | 0.5 divisions or 5 mV |
| @ 40 MHz | 123B: 4 divisions | |
| 124B and 125B: 1.5 divisions | ||
| @ 60 MHz | 123B: N/A | |
| 124B and 125B: 4 divisions | ||
| Slope | Positive, negative | |
| Advanced scope functions | ||
| Display modes | Normal | Captures up to 25 ns glitches and displays analog-like persistence waveform |
| Smooth | Suppresses noise from a waveform | |
| Glitch off | Does not capture glitches between samples | |
| Envelope | Records and displays the minimum and maximum of waveforms over time | |
| Auto set (Connect-and-View™) | Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level. | |
| Dual input meter | ||
| The accuracy of all measurements is within ±(% of reading + number of counts) from 18 °C to 28 °C. | ||
| Add 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. For voltage measurements with 10:1 probe, add probe uncertainty +1%. More than one waveform period must be visible on the screen. |
| Input A and input B | ||
| DC voltage (VDC) | ||
| Ranges | 500 mV, 5 V, 50 V, 500 V, 750 V | |
| Accuracy | ±(0.5% +5 counts) | |
| Common mode rejection (CMRR) | >100 dB @ dc, >60 dB @ 50, 60, or 400 Hz | |
| Full scale reading | 5000 counts | |
| True-rms voltages (V ac and V ac+dc) | ||
| Ranges | 500 mV, 5 V, 50 V, 500 V, 750 V | |
| Accuracy for 5% to 100% of range (DC coupled) | DC to 60 Hz (V ac+dc) | ±(1% +10 counts) |
| 1 Hz to 60 Hz (V ac) | ±(1% +10 counts) | |
| Accuracy for 5% to 100% of range (AC or dc coupled) | 60 Hz to 20 kHz | ±(2.5% +15 counts) |
| DC rejection (only VAC) | >50 dB | |
| Common mode rejection (CMRR) | >100 dB @ dc | |
| >60 dB @ 50, 60, or 400 Hz | ||
| Full scale reading | 5000 counts, reading is independent of any signal crest factor. | |
| Peak | ||
| Modes | Max peak, Min peak, or pk-to-pk | |
| Ranges | 500 mV, 5 V, 50 V, 500 V, 2200 V | |
| Accuracy | Accuracy Max peak or Min peak | 5% of full scale |
| Accuracy Peak-to-Peak | 10% of full scale | |
| Full scale reading | 500 counts | |
| Frequency (Hz) | ||
| Ranges | 123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz | |
| 124B and 125B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz | ||
| Frequency range | 15 Hz (1 Hz) to 50 MHz in continuous autoset | |
| Accuracy @1 Hz to 1 MHz | ±(0.5% +2 counts) | |
| 10,000 counts | ||
| RPM | ||
| Max reading | 50.00 kRPM | |
| Accuracy | ±(0.5% +2 counts) | |
| Duty cycle (PULSE) | ||
| Range | 2% to 98% | |
| Frequency range | 15 Hz (1 Hz) to 30 MHz in continuous autoset | |
| Pulse width (PULSE) | ||
| Frequency range | 15 Hz (1 Hz) to 30 MHz in continuous autoset | |
| Full scale reading | 1000 counts | |
| Amperes (AMP) | ||
| With current clamp | Ranges | Same as V dc, V ac, V ac+dc, or PEAK |
| Scale factors | 0.1 mV/A, 1 mV/A, 10 mV/A, 100 mV/A, 400 mV/A, 1 V/A, 10 mV/mA | |
| Accuracy | Same as V dc, V ac, V ac+dc, or PEAK (add current clamp uncertainty) | |
| Temperature (TEMP) with optional temperature probe | ||
| Range | 200 °C/div (200 °F/div) | |
| Scale factor | 1 mV/°C and 1 mV/°F | |
| Accuracy | As V dc (add temp. probe uncertainty) | |
| Decibel (dB) | ||
| 0 dBV | 1 V | |
| 0 dBm (600 Ω /50 Ω) | 1 mW referenced to 600 Ω or 50 Ω | |
| dB on | V dc, V ac, or Vac+dc | |
| Full scale reading | 1000 counts | |
| Crest factor (CREST) | ||
| Range | 1 to 10 | |
| Full scale reading | 90 Counts | |
| Phase | ||
| Modes | A to B, B to A | |
| Range | 0 to 359 degrees | |
| Resolution | 1 degree | |
| Power (125B only) | ||
| Configurations | 1 phase / 3 phase 3 conductor balanced loads (3 phase: fundamental component only, AUTOSET mode only) | |
| Power factor (PF) | Ratio between watts and VA range - 0.00 to 1.00 | |
| Watt | RMS reading of multiplying corresponding samples of input A (volts) and input B (amperes) | |
| Full scale reading | 999 counts | |
| VA | Vrms x Arms | |
| Full scale reading | 999 counts | |
| VA reactive (var) | √((VA)2-W2) | |
| Full scale reading | 999 counts | |
| Vpwm | ||
| Purpose | To measure on pulse width modulated signals, like motor drive inverter outputs | |
| Principle | Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency | |
| Accuracy | As Vrms for sinewave signals | |
| Input A to common | ||
| Ohm (Ω) | ||
| Ranges | 123B and 124B | 500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ |
| 125B | 50 Ω, 500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ | |
| Accuracy | ±(0.6% + 5 counts) 50 Ω ±(2% + 20 counts) | |
| Full scale reading | 50 Ω to 5 MΩ - 5000 counts, 30 MΩ - 3000 counts | |
| Measurement current | 0.5 mA to 50 nA, decreases with increasing ranges | |
| Open circuit voltage | <4 V | |
| Continuity (Cont) | ||
| Beep | <(30 Ω ±5 Ω) in 50 Ω range | |
| Measurement current | 0.5 mA | |
| Detection of shorts of | ≥1 ms | |
| Diode | ||
| Measurement voltage | @0.5 mA | >2.8 V |
| @open circuit | <4 V | |
| Measurement current | 0.5 mA | |
| Polarity | + on input A, - on COM | |
| Capacitance (CAP) | ||
| Ranges | 50 nF, 500 nF, 5 μF, 50 μF, 500 μF | |
| Full scale reading | 5000 counts | |
| Measurement current | 500 nA to 0.5 mA, increases with increasing ranges | |
| Advanced meter functions | ||
| Zero Set | Set actual value to reference | |
| AutoHold (on A) | Captures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals. | |
| Fixed decimal point | Activated by using attenuation keys | |
| Cursor Readout (124B and 125B) | ||
| Sources | A, B | |
| Single vertical line | Average, min and max readout | |
| Average, min, max and time from start of readout (in ROLL mode; instrument in HOLD) | ||
| Min, max and time from start of readout (in RECORDER mode; instrument in HOLD) | ||
| Harmonics values in POWER QUALITY mode. | ||
| Dual vertical lines | Peak-peak, time distance and reciprocal time distance readout | |
| Average, min, max and time distance readout (in ROLL mode; instrument in HOLD) | ||
| Dual horizontal lines | High, low and peak-peak readout | |
| Rise or fall time | Transition time, 0%-level and 100%-level readout (manual or auto leveling; auto leveling only possible in single channel mode) |
|
| Accuracy | As oscilloscope accuracy | |
Fluke 120B Series Industrial ScopeMeter handheld Oscilloscopes
Includes:
- Fluke 123B Hand-Held Oscilloscope
- Shielded Test Leads with Black Ground Leads
- Test Lead Black (for Grounding)
- Hook Clips (red, blue)
- Banana-to-BNC Adapters (black, x1)
- USB Angled Adapter
- WiFi USB Adapter*
- Switch Mode Power Supply, Adapter/Battery Charger
- Rechargeable Li-ion Battery Pack
- Soft Carrying Case
- Magnetic Hanger
- FlukeView® ScopeMeter® Software for Windows®
- Screen Protector
Accessories: Fluke 120B Series Industrial ScopeMeter handheld Oscilloscopes
Cables (1)
- Fluke OC4USB USB Interface Cable
Current clamps (9)
- Fluke 80i-110s AC/DC Current Clamp
- Fluke i1010 AC/DC Current Clamp
- Fluke i200s AC Current Clamp
- Fluke i30 AC/DC Current Clamp
- Fluke i3000s Flex-24 AC Current Clamp, 610 mm (24 in.)
- Fluke i3000s Flex-36 AC Current Clamp, 915 mm (36 in.)
- Fluke i400 AC Current Clamp
- Fluke i410 AC/DC Current Clamp
- Fluke i5S AC Current Clamp
Probes (1)
- Fluke i1000s AC Current Probe
Current probes (1)
- Fluke i310s Current Probe