Fluke MDA-510 and MDA-550 Motor Drive Analyzers
Advanced Motor Drive Analysis with Trusted Precision
Product Overview
Fluke MDA-510 and MDA-550 Motor Drive Analyzers Price in Bangladesh
Fluke MDA 510 and MDA 550 Motor Drive Analyzers are designed for accurate motor drive testing and diagnostics, making the Fluke MDA-510 and MDA-550 Motor Drive Analyzers Price in Bangladesh a frequently searched topic among industrial engineers and maintenance professionals. These analyzers provide reliable measurement capability for troubleshooting motor drive systems, improving operational efficiency, and supporting preventive maintenance tasks.
Built for demanding industrial environments, the analyzers combine durable construction with user friendly operation to simplify complex diagnostic procedures. They help technicians evaluate motor drive performance, identify electrical irregularities, and maintain system stability with greater confidence. Their advanced analysis capability supports efficient troubleshooting, reducing downtime and improving workflow productivity.
The compact and practical design allows convenient use in field inspections, maintenance operations, and industrial service applications. With clear data presentation and dependable performance, these analyzers assist professionals in monitoring electrical systems accurately and efficiently. Their reliable functionality makes them suitable for continuous use in manufacturing facilities, industrial plants, and technical maintenance environments.
Designed with professional grade engineering and long lasting durability, the motor drive analyzers deliver stable operation and dependable results in challenging working conditions. They are an excellent solution for users seeking accurate diagnostics, efficient motor drive analysis, and reliable long term performance for industrial electrical systems.
Key Features: Fluke MDA-510 and MDA-550 Motor Drive Analyzers
- Guided testing with graphical step-by-step voltage and current connection diagrams makes setup and connection to variable frequency drives easier than ever
- Preset measurement profiles collect data based on the chosen test procedure and reduce the need for complex configuration
- Built-in report writing capabilities make it easy to produce professional as-found and as-left motor-drive troubleshooting reports
Specifications
Specifications: Fluke MDA-510 and MDA-550 Motor Drive Analyzers
| Measurement Function | |
|---|---|
| DC voltage (V dc) | |
| Maximum voltage with 10:1 or 100:1 probe | 1000 V |
| Maximum resolution with 10:1 or 100:1 probe | 1 mV |
| Full scale reading | 999 counts |
| Accuracy at 4 s to 10 us/div | ±(3 % + 6 counts) |
| AC voltage (V ac) | |
| Maximum voltage with 10:1 or 100:1 probe | 1000 V |
| Maximum resolution with 10:1 or 100:1 probe | 1 mV |
| Full scale reading | 999 counts |
| 50 Hz | ±(3 % + 10 counts) - 0.6 % |
| 60 Hz | ±(3 % + 10 counts) - 0.4 % |
| 60 Hz to 20 kHz | ±(4 % + 15 counts) |
| 20 kHz to 1 MHz | ±(6 % + 20 counts) |
| 1 MHz to 25 MHz | ±(10 % + 20 counts) |
| True-rms voltage (V ac+dc) | |
| Maximum voltage with 10:1 or 100:1 probe | 1000 V |
| Maximum resolution with 10:1 or 100:1 probe | 1 mV |
| Full scale reading | 1100 counts |
| DC to 60 Hz | ±(3 % + 10 counts) |
| 60 Hz to 20 kHz | ±(4 % + 15 counts) |
| 20 kHz to 1 MHz | ±(6 % + 20 counts) |
| 1 MHz to 25 MHz | ±(10 % + 20 counts) |
| PWM voltage (V pwm) | |
| Purpose | To measure on pulse width modulated signals, like motor drive inverter outputs |
| Principle | Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency |
| Accuracy | As Vac+dc for sinewave signals |
| Peak voltage (V peak) | |
| Modes | Max peak, min peak, or pk-to-pk |
| Maximum voltage with 10:1 or 100:1 probe | 1000 V |
| Maximum resolution with 10:1 or 100:1 probe | 10 mV |
| Accuracy | |
| Max peak, min peak | ±0.2 division |
| Pk-to-pk | ±0.4 division |
| Full scale reading | 800 counts |
| General Specification | |
|---|---|
| Current (AMP) with current clamp | |
| Ranges | Same as V ac, Vac+dc or V peak |
| Scale Factors | 0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50mV/A, 100 mV/A, 200 mV/A, 400 mV/A |
| Accuracy | Same as Vac, Vac+dc or V peak (add current clamp accuracy) |
| Frequency (Hz) | |
| Range | 1.000 Hz to 500 MHz |
| Full scale reading | 999 counts |
| Accuracy | ±(0.5 % + 2 counts) |
| Voltage/Herz ratio (V/Hz) | |
| Purpose | To show the measured V PWM value (see V PWM) divided by the fundamental frequency on variable ac motor speed drives |
| Accuracy | % Vrms + % Hz |
| Voltage unbalance drive input | |
| Purpose | To show the highest percentage difference of one of the phase vs average of the 3 true-rms voltages |
| Accuracy | Indicative percentage based on Vac+dc values |
| Voltage unbalance drive output and motor input | |
| Purpose | To show the highest percentage difference of one of the phase vs average of the 3 PWM voltages |
| Accuracy | Indicative percentage based on V PWM values |
| Current unbalance drive input | |
| Purpose | To show the highest percentage difference of one of the phase vs average of the 3 AC current values |
| Accuracy | Indicative percentage based on Aac+dc values |
| Current unbalance drive output and motor input | |
| Purpose | To show the highest percentage difference of one of the phase vs average of the 3 AC current values |
| Accuracy | Indicative percentage based on A ac values |
| Rise and fall time | |
| Readings | Voltage difference (dV), time difference (dt), voltage vs time difference (dV/dt), overshoot |
| Accuracy | As oscilloscope accuracy |
| Harmonics and spectrum | |
| Harmonics | DC to 51st |
| Spectrum ranges | 1…9 kHz, 9-150 kHz (20 MHz filter on), up to 500 MHz (voltage modulation) |
| Shaft voltage | |
| Events / second | Indicative percentage based on rise and fall time (Impulse discharges) measurements |
| Report data capture | |
| Number of screens | Typical 50 screens can be saved in reports (depends on compression ratio) |
| Transfer to PC | Using 2 GB USB stick or mini-USB to USB cable and FlukeView™ 2 for ScopeMeter™ test tool |
| Probe settings | |
| Voltage probe | 1:1, 10:1, 100:1, 1000:1, 20:1, 200:1 |
| Current clamp | 0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50 mV/A, 100 mV/A, 200 mV/A, 400 mV/A |
| Shaft voltage probe | 1:1, 10:1, 100:1 |