Hioki BT3554-50 Battery Tester
Accurate Battery Diagnostics for Reliable Power Systems
Product Overview
Hioki BT3554-50 Battery Tester Price in Bangladesh
Portable battery testing equipment is essential for maintaining the performance and reliability of backup power systems, and Hioki BT3554-50 Battery Tester Price in Bangladesh is widely searched by engineers, technicians, and industrial professionals seeking dependable testing solutions. Designed for advanced battery diagnostics, the Hioki BT3554-50 delivers accurate internal resistance and voltage measurements for UPS batteries and other critical power applications.
This professional battery tester allows users to evaluate battery condition without disconnecting the battery from its system, making maintenance faster and more efficient. Its advanced noise reduction technology ensures stable and accurate readings even in demanding industrial environments. The device supports quick measurement and automatic data storage, helping technicians improve workflow efficiency during routine inspections and preventive maintenance.
Built with a durable and portable design, the tester is suitable for power plants, telecommunications, data centers, industrial facilities, and electrical maintenance operations. The user friendly interface, fast response capability, and reliable diagnostic performance make it an ideal choice for professionals handling large battery systems. Optional wireless connectivity and software integration also simplify report generation and data management for modern maintenance operations.
The Hioki BT3554-50 is engineered for long term durability, precision, and safe operation in critical environments. Its efficient testing performance and dependable build quality make it a trusted solution for battery health analysis and preventive maintenance applications.
Key Features: Hioki BT3554-50 Battery Tester
- Battery measurement can be performed while the battery is connected to its host device, without taking it offline
- Measure and save data in as fast as 2 seconds, a 60% improvement from the legacy 3554
- Instantaneously diagnose battery degradation (PASS, WARNING, FAIL) by measuring internal resistance and voltage (*1)
- Noise reduction technology improves noise resistance
- Screen and audio (*2) guidance simplifies measurement
- Measurement data is linked to site information and saved, reducing management man-hours
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross (*3) or to an Excel® file. (Wireless Adapter Z3210 is necessary)
- New protector delivers better ergonomic hold and durability in the field.
Specifications
Specifications: Hioki BT3554-50 Battery Tester
Accuracy guaranteed: 1 year
| BT3554-50 | BT3554-51 | BT3554-52 | ||||
| Resistance measurement range | 3 mΩ (max. display 3.100 mΩ, resolution 1 μΩ) to 3 Ω (max. display 3.100 Ω, resolution 1 mΩ), 4 ranges Accuracy: ±0.8 % rdg ±6 dgt (3 mΩ range: ±1.0 % rdg ±8 dgt) Testing source frequency: 1 kHz ±30 Hz With function for avoiding noise frequency enabled: 1 kHz ±80 Hz Testing current: 160 mA (3m/30 mΩ range), 16 mA (300 mΩ range), 1.6 mA (3 Ω range) Open terminal Voltage: 5 V peak |
|||||
| Voltage measurement range | ± 6 V (max. display ±6.000 V, resolution: 1 mV) to ± 60 V (max. display ±60.00 V, resolution: 10 mV), 2 ranges, Accuracy: ±0.08 % rdg ±6 dgt | |||||
| Temperature measurement accuracy | Measurement range: -10°C to 60°C (14°F to 140°F), Maximum display: 60.0°C (140.0°F), Resolution 0.1°C (0.1°F), Measurement accuracy*: ±1.0°C (±1.8°F) * When using the Clip Type Lead with Temperature Sensor 9460. * When using the Temperature Probe 9451, add ±0.5°C (±0.9°F) (cable length: 1.5 m [59.1"]). * When using the Temperature Probe 9451S, add ±0.5°C (±0.9°F) (cable length: 0.1 m [3.94"]). BT3554-50 standalone accuracy with simulated input: ±0.5°C (±0.9°F) |
|||||
| Absolute max. input voltage | 60 V DC max. (No AC input) | |||||
| Measurement time | 100 ms | |||||
| Response time | Approx. 1.6 sec. | |||||
| Comparator | Compares measured values with set threshold values to make judgments and reports them to the user. Judgment notification method: Results are displayed as shown below (segment) and beeping tones sound When the Voltage value (high): Resistance value (low)= PASS, Resistance value (medium)= WARNING, Resistance value (high)= FAIL When the Voltage value (low): Resistance value (low)= WARNING, Resistance value (medium)= WARNING, Resistance value (high)= FAIL If the judgment result is WARNING or FAIL, the audio tone is accompanied by a red backlight. User-selectable voltage judgment method: ABS (absolute value judgment), POL (polarity judgment ) Savable settings: 200 tables |
|||||
| Memory functionality | Operation: Save, load, and delete measurement data, Save and delete profile information, Number of data sets: 6000, Memory architecture: 500 data sets per unit (12 units) Saved data: Saved measurement data is linked to profile information. 1. Measurement data: Data can be saved, loaded, and deleted by operating the instrument. -1. Date and time -2. Resistance value, voltage value, and temperature -3. Comparator threshold value and judgment result 2. Profile information: Profile information can be saved, loaded, and deleted using a supported application (GENNECT Cross or GENNECT One). -1. Profile numbers: 1 to 100 (Data (2), (3), and (4) below are saved for each profile number) -2. Location: User-defined comment such as location of UPS -3. Device information: User-defined comment such as UPS management number -4. Battery number: 1 to 500 (start number, end number) |
|||||
| Measurement Navigator | Operation: Announces the next battery number to be measured via a screen display and audio guidance. Audio output is generated by a connected mobile device when using the Z3210 and a supported application (GENNECT Cross). Preparations: Profile information that's been registered with a supported application (GENNECT Cross or GENNECT One) must be transferred to the instrument. |
|||||
| Communication interface | USB Bluetooth® wireless communications (when Z3210 installed) |
|||||
| Other functions | Temperature measurement (-10.0 to 60.0 °C), Zero-adjustment, Hold, Auto-hold, Auto-memory, Auto-power-save, Clock | |||||
| Power supply | LR6 (size AA) alkaline battery ×8 Rated supply voltage: 1.5 V DC × 8 (Nickel metal hydride batteries may be used. However, the battery life display is not supported in this configuration.) Continuous operating time: Approx. 8.3 hr. (without Z3210 installed), Approx. 8.2 hr. (with Z3210 installed and wireless communications active) |
|||||
| Dimensions and mass | 199 mm (7.83 in)W × 132 mm (5.20 in)H × 60.6 mm (2.39 in)D (with protector), 960 g (33.9 oz) (including batteries and protector) | |||||
| Included accessories | Carrying Case C1014 ×1, Protector Z5041 ×1, Fuse Set Z5050 ×1, 0 Adj Board ×1, Neck strap ×1, USB cable ×1, Application software CD (GENNECT One) ×1, AA alkaline battery (LR6) ×8, User Manual ×1 | |||||
| Instrument only | With Pin Type Lead 9465-10 | With Pin Type Lead L2020 | ||||