Hioki PQ3198 Power quality analyzers

Hioki PQ3198  Power quality analyzers

Hioki PQ3198 Power quality analyzers

Precision Power Quality Analysis for Industrial Reliability

Product Overview

Hioki PQ3198 Power quality analyzers Price in Bangladesh

Hioki PQ3198 is engineered for advanced electrical monitoring and professional diagnostics, making Hioki PQ3198 Power quality analyzers Price in Bangladesh a trusted solution for industrial facilities, utility services, and commercial power systems. Designed to deliver highly accurate measurements, this analyzer helps engineers and technicians identify power quality issues, monitor harmonics, and maintain stable electrical performance with confidence.

The analyzer supports comprehensive monitoring of single phase and three phase electrical systems, allowing users to evaluate voltage fluctuations, current behavior, power factor, harmonics, transient events, and energy performance. Its advanced recording capabilities enable long term monitoring and detailed waveform capture, helping professionals quickly investigate electrical abnormalities and improve overall system efficiency. The device also supports continuous gapless recording for reliable power quality analysis in demanding applications.

Built with a rugged and portable design, the Hioki PQ3198 is suitable for industrial maintenance, preventive inspections, energy audits, and troubleshooting applications. The intuitive interface and intelligent setup functions simplify operation, allowing users to configure measurements quickly and efficiently. Its advanced analysis software support also helps generate professional reports for accurate documentation and performance evaluation.

Hioki PQ3198 power quality analyzers is widely recognized for its reliability, measurement accuracy, and professional grade performance in electrical diagnostics. It helps organizations reduce downtime, improve energy efficiency, and protect sensitive equipment from power related issues. With durable construction and advanced harmonics analysis capabilities, this analyzer is an excellent choice for professionals seeking dependable power quality monitoring solutions for modern electrical systems.

Key Features: Hioki PQ3198 Power quality analyzers

  • Verify power problems in accordance with the IEC61000-4-30 Edition 3 Class A standard
  • High accuracy and continuous gapless recording
    (V: ±0.1% of nominal voltage, A: ±0.1% rdg. ±0.1% f.s., W: ±0.2% rdg. ±0.1% f.s.)
  • Broadband voltage range lets you measure even high-order harmonic (supraharmonic) components of up to 80 kHz
  • Maximum 6000 V peak transient voltage up to 700 kHz
  • Measure up to 6000 A AC
  • Two systems of power measurement and efficiency calculation for (ch 1, ch 2, ch 3) and ch 4
  • Make simple measurements of inverters with 40 to 70 Hz fundamental frequency and max. 20 kHz carrier frequency
  • Easily create reports with bundled PQ ONE application software 
  • Optional GPS BOX for synchronizing multiple devices
Specifications

Specifications: (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

Measurement line type Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel for voltage, current, power measurement (AC or DC measurement)
Voltage ranges Voltage measurement: 600.00 V rms
Transient measurement 6.0000 kV peak
Current ranges 500.00 mA to 5.0000 kA AC (depends on current sensor in use)
Power ranges 300.00 W to 3.0000 MW (determined automatically based on voltage and current range in use)
Basic accuracy Voltage: ±0.1% of nominal voltage
Current: ±0.1 % rdg. ±0.1 % f.s. + current sensor accuracy
Active power: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy
Measurement items 1. Transient voltage : 2 MHz sampling
2. Frequency cycle : Calculated as one cycle, 40 to 70 Hz
3. Voltage (1/2) RMS: one cycle calculation refreshed every half cycle
Current (1/2) RMS: half-cycle calculation
4. Voltage swell, Voltage dips, Voltage interruption
5. Inrush current
6. Voltage waveform comparison
7. Instantaneous flicker value: As per IEC61000-4-15
8. 200 ms frequency: Calculated as 10 or 12 cycles,40 to 70 Hz
9. 10 sec frequency: Calculated as the whole-cycle time during the specified 10 s period, 40 to 70 Hz
10. Voltage waveform peak, Current waveform peak
11. Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Reactive energy, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor, and efficiency
12. High-order harmonic* component (voltage/ current): 2 kHz to 80 kHz
*Supraharmonic
13. Harmonic/ Harmonic phase angle (voltage/ current), Harmonic power: 0th to 50 th orders
14. Harmonic voltage-current phase angle: 1th to 50 th orders
15. Total harmonic distortion factor (voltage/ current)
16. Inter harmonic (voltage/ current): 0.5 th to 49.5 th order
17. K Factor (multiplication factor)
18. IEC Flicker, Δ V10 Flicker
19. Mains signaling voltage
Record Repeated ON: 1 year, Maximum recording event: 9999 × 366 days (up to 9999 events per day)
Repeated off: 35 days, maximum recording event: 9999 events
Interfaces SD/SDHC memory card, LAN (HTTP server function / FTP function), USB2.0 (for communication)
Display 6.5-inch TFT color LCD (640 × 480 dots)
Power supply AC adapter Z1002 (100 V to 240 V AC, 50/60 Hz, rated current 1.7 A), Battery Pack Z1003 (Continuous use: 180 minutes, Charging time: Max. 5 hr 30 m with AC adapter)
Dimensions and mass 300 mm (11.81 in)W × 211 mm (8.31 in)H × 68 mm (2.68 in)D, 2.6 kg (91.7 oz) (including Battery Pack Z1003)
Included accessories Instruction manual ×1, Measurement guide ×1, Voltage Cord L1000 ×1 set (Red/ Yellow/ Blue/ Gray each 1, Black 4, 3m (9.84ft) length, Alligator clip ×8), Spiral tube x20, Color clip, AC Adapter Z1002 ×1, Strap ×1, USB cable (1 m 3.28 ft length) ×1, Battery pack Z1003 ×1, SD Memory Card 2GB Z4001 ×1, Application software (PQ ONE) ×1