Fluke CertiFiber® Pro Optical Loss Test Set

  • Home
  • Products
  • Fluke CertiFiber® Pro Optical Loss Test Set
Fluke CertiFiber® Pro Optical Loss Test Set

Fluke CertiFiber® Pro Optical Loss Test Set

Precision fiber certification for dependable network performance

Product Overview

Fluke CertiFiber® Pro Optical Loss Test Set Price in Bangladesh

Fluke CertiFiber® Pro Optical Loss Test Set is a professional fiber optic certification solution, and network specialists searching for the Fluke CertiFiber® Pro Optical Loss Test Set Price in Bangladesh often need a reliable instrument for validating fiber optic installations and maintaining high network performance standards. Designed for accurate optical loss measurement and fiber certification, this test set helps technicians verify link quality with confidence.

Built to support modern fiber networks, the CertiFiber® Pro simplifies testing procedures while delivering dependable and consistent results. It enables technicians to identify performance issues efficiently, helping ensure that fiber infrastructure meets operational requirements. This contributes to improved network reliability and reduces the likelihood of connectivity problems caused by installation defects or signal loss.

The intuitive interface enhances usability by providing clear test information and streamlined operation. Technicians can perform certification tasks quickly and efficiently, reducing testing time while maintaining accuracy. Its user friendly design makes it suitable for data centers, enterprise networks, telecommunications systems, and other fiber optic environments where dependable performance is essential.

Durability is a key strength of the Fluke CertiFiber® Pro Optical Loss Test Set. Engineered for professional field applications, it is built to withstand demanding working conditions while maintaining reliable operation. Its robust construction ensures long term performance, making it a trusted tool for installation teams, contractors, and network maintenance professionals.

By supporting accurate fiber certification and optical loss analysis, the device helps reduce troubleshooting efforts and supports proactive maintenance practices. Early identification of fiber performance issues allows organizations to maintain efficient network operations and improve long term infrastructure reliability.

The Fluke CertiFiber® Pro Optical Loss Test Set combines precision, ease of use, and rugged durability in a comprehensive fiber testing solution. Its advanced capabilities make it an excellent choice for professionals who require dependable fiber certification and optical network diagnostics.

Specifications

Specifications: Fluke CertiFiber® Pro Optical Loss Test Set

Specification Details
Input Connector Interchangeable connector adapter (LC standard, SC, ST and FC optional)
Detector Type InGaAs
Wavelengths 850 nm, 1300 nm, 1310 nm, 1550 nm
Power Measurement Range 0 dBm to -65 dBm (850 nm), 0 dBm to -70 dBm (all other wavelengths)
Power Measurement Uncertainty < ± 5% ± 32 pW
Measurement Linearity < ± 0.1 dB
Re-calibration Period 1 year
Integrated Wi-Fi Meets IEEE 802.11 a/b/g/n; dual band (2.4 GHz and 5 GHz)
Notes 1. ± 100 pW at 850 nm
2. Conditions: Power level 100 μW (-10 dBm), CW, ambient temperature 23°C ± 1°C, SC/UPC connector, 5 min warm-up, NIST traceable.
3. Linearity: -3 dBm to -55 dBm at 850 nm & 1310 nm under 23°C ± 1°C and 5 min warm-up

 

Loss/Length Specifications

Specification CertiFiber Pro Multimode Modules CertiFiber Pro Singlemode Modules
Testing Speeds Smart Remote: < 3 sec
Far End Source: ≤ 2 sec
Loopback: ≤ 2 sec
Smart Remote: < 3 sec
Far End Source: ≤ 2 sec
Loopback: ≤ 2 sec
Input/Output Connectors Interchangeable connector adapter (LC standard, SC, ST, FC optional) Interchangeable connector adapter (LC standard, SC, ST, FC optional)
Launch Condition Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3, IEC 61280-4-1 Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3, IEC 61280-4-1
Fiber Types Tested 50/125 µm or 62.5/125 µm Singlemode
Source Type and Wavelengths LED source: 850 nm ± 30 nm
1300 nm ± 20 nm
Fabry-Perot laser diode: 1310 nm ± 20 nm
1550 nm ± 30 nm
Maximum Length Measurement 12 km 130 km
Length Measurement Accuracy ± 1.5 m plus ± 1% of length ± 1.5 m plus ± 1% of length
Output Power (Nominal) ≥ -24 dBm with EF-TRC ≥ -4 dBm
Output Power Stability ± 0.05 dB over 8 hours
± 0.03 dB over 15 minutes
± 0.1 dB over 8 hours
± 0.08 dB over 15 minutes

 

Loss/Length Specifications (continued)

Specification Details
Source Wavelengths 850 nm, 1300 nm, 1310 nm, 1550 nm
Power Measurement Range 0 dBm to -65 dBm (850 nm)
0 dBm to -70 dBm (all other wavelengths)
Power Measurement Uncertainty¹² < ± 5% ± 32 pW
Measurement Linearity³ < ± 0.1 dB
Re-calibration Period 1 year

 

Footnotes:

  1. ±100 pW at 850 nm

  2. Under the following conditions:
     • Power level: 100 μW (-10 dBm), continuous wave (CW)
     • Wavelengths: 850 nm and 1310 nm
     • Beam: Divergent, NA = 0.20 for 50/125 μm and NA = 0.14 for 9/125 μm
     • Temperature: 23° ± 1°C
     • Connector: SC/UPC with ceramic ferrule
     • Warm-up time: After 5 minutes
     • Calibration: Traceable to NIST

  3. Range: -3 dBm to -55 dBm at 850 nm and 1310 nm
     • Temperature: 23° ± 1°C
     • Warm-up time: After 5 minutes

 

Selected Specifications (VFL)

Title Requirement
Output Power >-5 dBm <0 dBm SMF-28 singlemode fiber Continuous wave SC/UPC connector
Operating Wavelength 650 nm nominal
Output Modes Continuous wave
Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector Adapter 2.5 mm universal
Laser Safety Class II CDRH
Over operating temperature range

 

Environmental Specifications

Title Requirement
Operating Temperature -10° C to 45° C
Storage Temperature -10° C to +60° C
Operating Relative Humidity 0 % to 90 %, 32 °F to 95 °F (0° C to 35° C)
0 % to 70 %, 95 °F to 113 °F (35° C to 45° C)
Vibration Random, 2 g, 5 Hz-500 Hz
Shock 1 m drop test with and without module and adapters
Safety CSA C22.2 No. 1010.1: 1992
EN 61010-1 1st Edition + Amendments 1, 2
Pollution Degree 2
Altitude Operating: 4,000 m
Storage: 12,000 m
EMC EN 61326–1
Features

Unique Features: Fluke CertiFiber® Pro Optical Loss Test Set

  • Versiv enables users to accomplish more than ever before with a cable tester, accelerating every step of the testing process
  • ProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time.
  • Taptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels.
  • LinkWare management software provides unmatched analysis of test results and professional test reports

 

Standards:

  • Allows combined OLTS Tier 1 (basic), OTDR Tier 2 (extended) certification, end-face inspection and reporting when paired with OptiFiber™ Pro OTDR
  • Set reference wizard verifies test reference cords (TRCs) per ISO/IEC 14763-3 and eliminates negative loss errors
  • Encircled Flux compliant optical launch conditions required by ANSI/TIA and ISO/IEC standards
  • Double-ended fiber optic end-face certification to IEC 61300-3-35

 

Performance:

  • Three-second Autotest – (four times faster than legacy testers) includes optical loss measurement of two fibers at two wavelengths with distance measurement and optical loss budget calculation
  • Provides automatic Pass/Fail analysis to industry standards or custom test limits
  • Identifies incorrect test procedures resulting in negative loss results
  • Double ended Pass/Fail certification of fiber optic connector end-faces
  • Graphical indication of problem areas on fiber end-faces due to contamination, pits, chips and scratches
  • Interchangeable power meter adapters available for all typical connector types (SC, ST, LC and FC) to enable the most accurate 1-jumper reference method
  • Built-in visual fault locator for basic troubleshooting and polarity determination
  • Dual wavelength measurement capability on a single fiber allows the tester to be used in applications that require only one fiber link.
  • Compliant with TIA-526-14-B and IEC 61280-4-1 Encircled Flux requirements with no additional equipment or procedures
  • Integrated Wi-Fi allows you to easily upload results to LinkWare Live